logo
Send Message
Home > products >
Transformer Tester
>
Accurate Diagnosis Of Transformer Internal Faults With XHBX1502 Winding Deformation Tester SFRA With Impedance

Accurate Diagnosis Of Transformer Internal Faults With XHBX1502 Winding Deformation Tester SFRA With Impedance

Product Details:
Place of Origin: Xi'an city,Shaanxi,China
Brand Name: XZH TEST
Certification: CE ISO
Model Number: XHBX1502
Detail Information
Place of Origin:
Xi'an city,Shaanxi,China
Brand Name:
XZH TEST
Certification:
CE ISO
Model Number:
XHBX1502
Highlight:

High Light

Highlight:

Impedance Transformer Internal Faults

,

Winding Deformation Tester SFRA

,

Accurate Diagnosis Transformer Internal Faults

Trading Information
Minimum Order Quantity:
1unit
Price:
EXW 6430
Packaging Details:
wooden packaging
Payment Terms:
T/T
Supply Ability:
500 units per month
Product Description

Sweep Frequency Response Analyzer with impedance  XHBX1502

Accurate Diagnosis Of Transformer Internal Faults With XHBX1502 Winding Deformation Tester SFRA With Impedance 0

 

Description

According to the measurement of the characteristic parameters of the internal winding of the transformer, the XHBX1502 transformer winding deformation tester adopts the internal fault frequency response analysis (FRA) method developed by the developed countries in the world, which can make an accurate judgment on the internal fault of the transformer.

The XHBX1502 transformer winding deformation tester quantifies the response changes of the internal winding parameters of the transformer in different frequency domains, and determines the internal transformer according to the magnitude of the change, the magnitude of the frequency response change, and the change of the regional and frequency response. The degree of change of the winding, and then can be judged according to the measurement results whether the transformer has been seriously damaged and whether it needs to be overhauled.


 

Main features

1. Adopt control uses high-speed, high-integration microprocessor.

2. Communication USB port between laptop and instrument.

3. Wireless Bluetooth port (optional) for communication between laptop and instrument.

4. The hardware movement adopts DDS special digital high-speed frequency sweeping technology (USA), which can accurately diagnose faults such as twisting, bulging, displacement, tilting, inter-turn short-circuit deformation and phase-to-phase contact short-circuit.

5. high-speed dual-channel 16-bit A / D sampling (field test to change the tap-changer, the waveform curve has a clear change).

6. The signal output amplitude software adjustment, the maximum amplitude peak is ± 10V.

7. The computer will automatically analyze the test results and generate e-documents (Word)

8. The instrument has the functions of linear sweep frequency measurement and segmented sweep frequency measurement dual measurement system, which is compatible with the current domestic two technical genre measurement modes.

9. The amplitude-frequency characteristic is in line with the national technical indicators of the amplitude-frequency characteristic tester. The abscissa (frequency) has two types of linear indexing and logarithmic indexing. Therefore, the printed curve can be a linear indexing curve or a logarithmic indexing curve, and the user can select according to actual needs.

10. Automatic data analysis system for detection data,

Horizontal comparison of winding similarities between A, B, and C phases,

The analysis results are:

① consistency is very good

② good consistency

③ poor consistency

④ consistency is very poor,

Longitudinal comparison A-A, B-B, C-C take the original data and the current data in the same phase to compare the winding deformation,

The analysis results are:

① normal winding

② mild deformation

③ moderate deformation

④ severe deformation

11. Can automatically generate Word e-documents for saving and printing.

12. The instrument fully meets the technical requirements of the power standard DL/T911-2004 "Frequency Response Analysis Method for Winding Deformation of Power Transformers.

 

Accurate Diagnosis Of Transformer Internal Faults With XHBX1502 Winding Deformation Tester SFRA With Impedance 1

                                                                                             Low voltage magnitude - frequency curve

Accurate Diagnosis Of Transformer Internal Faults With XHBX1502 Winding Deformation Tester SFRA With Impedance 2

                                     High voltage magnitude - frequency curve


 

Technical Parameter

 

 

 

 

 

Item Parameter

Linear scan distribution

 

Sweep test range: (10Hz) - (10MHz) 40000 sweep point, resolution of 0.25kHz, 0.5kHz and 1kHz
Segmented sweep test distribution

Segmented sweep test distribution

Sweep test range: (0.5kHz) - (1MHz), 2000 sweep point;

(0.5kHz) - (10kHz)

(10kHz) - (100kHz)

(100kHz) - (500kHz)

(500kHz) - (1000kHz)

Amplitude test range (-120dB) to (+20dB)
Amplitude test accuracy 0.1dB
Scanning frequency accuracy 0.01%
Signal input impedance 1MΩ
Signal output impedance 50Ω
Signal output amplitude ± 20V
In-phase test repetition rate 99.9%
Instrument size 300X340X120 (mm)
Instrument aluminum alloy box size 310X400X330 (mm)
Weight 10Kg